MDE-4863 Gasboy® 9800A or 2600A Pump Interface Kits Installation Instructions · October 2009 Page 7
Installation of the 9800A/2600A Pump Interface Kit
6 Slip the washers onto the threaded end of the standoffs. Screw the standoffs on the platform
base (see
Figure 5).
Note: Newer platforms will have two pre-fixed standoffs, in which case, the loose washers and
standoffs will not be used.
Figure 5: Side View
Washer
Standoff
6-32 Screw
CPU PCB
7 Connect the Pump I/F PCB to P8 of the CPU PCB.
8 Secure the PCB using two 6-32 screws.